THE SLIP RATING REQUIREMENTS – TABLE 3B – SA HB 198:2014
LOCATION WET PENDULUM TEST OIL-WET INCLINING PLATFORM TEST
STAIR TREADS, STAIRS & Landings- TABLES-3A D.T.S BCA APPLICATIONS
Stair Treads and a Stairway Landings- (Nosings Pendulum only) – DRY P3 R10
Stair Treads and a Stairway Landings- (Nosings Pendulum only) – WET P4 R11
RAMPS TABLE – 3A D.T.S BCA APPLICATIONS
Ramps not steeper than 1:14 gradient – DRY P3 R11
Ramps not steeper than 1:14 gradient – WET P4 R11
HOTELS, OFFICES, PUBLIC BUILDINGS, SCHOOLS AND KINDERGARTENS
Entry foyers hotel, office, public buildings and internal lift lobbies – WET P3 R10
Entry foyers hotel, office, public buildings and internal lift lobbies – TRANSITIONAL P2 R9
Entry foyers hotel, office, public buildings and internal lift lobbies – DRY P1 R9
Toilet facilities in office, hotels, shopping centres P3 R10
Hotel apartment bathrooms, ensuites and toilets P2 A
Hotel apartment kitchens and laundries P2 R9
SUPERMARKETS AND SHOPPING CENTRES
Fast food outlets, buffet food servery areas, food courts and fast food dining areas in shopping centres P3 R10
Shop and supermarket fresh fruit and vegetable areas P3 R10
Shop entry areas with external entrances P3 R10
Supermarket aisles (except fresh food areas) P1 R9
Other separate shops inside shopping centres – WET P3 R10
Other separate shops inside shopping centres – DRY P1 R9
LOADING DOCKS, COMMERCIAL KITCHENS, COLD STORES, SERVING AREAS
Loading docks under cover and commercial kitchens P5 R12
Serving areas behind bars in public hotels and clubs, cold stores & freezer P4 R11
SWIMMING POOLS AND SPORTING FACILITIES
Swimming pool ramps and stairs leading to water P5 C
Swimming pool ramps surrounds and communal shower rooms P4 B
Communal changing rooms P3 A
Undercover concourse areas of sports stadiums P3 R10
HOSPITALS & AGED CARE FACILITIES
Bathrooms and ensuites in hospitals and aged care facilities P3 B
Wards and corridors in hospital and aged care facilities P2 R9